Flow nozzle meter

DP flow nozzle meter assembly for liquids, gases and steam at high velocities, built to ISO 5167-3 or ASME MFC-3M with low remaining pressure drop.

The flow nozzle meter measures flow from the differential pressure across an ISA 1932, long radius or Venturi nozzle, according to ISO 5167-3 or ASME MFC-3M. It suits high-velocity services where erosion or cavitation is a risk, such as feedwater, steam, condensate and refined products in power plants, refineries, chemical plants, oil and gas production and CCS. It is supplied as a complete assembly with the nozzle, OPTIBAR DP transmitter, flow computer, valves and accessories, together with engineering, testing and documentation. Manufacturing and calibration are available up to 48", including a 20-point calibration at high Reynolds numbers, for example per ASME PTC.

Specifications

Nozzle Types
ISA 1932, long radius or Venturi nozzle
Standards
ISO 5167-3 or ASME MFC-3M
Manufacturing Size
Up to 48"
Calibration Size
Up to 48"
Special Calibration
20-point calibration at high Reynolds numbers (e.g. acc. to ASME PTC)
Communication Options
HART 7, Foundation fieldbus and Profibus-PA
Redundancy
1oo2, 2oo3
Functional Safety
SIL 2/3 certified versions
Hazardous Area Approvals
Ex ia, Ex d, Ex t
DP Transmitter
3-D linearised OPTIBAR