Skip to content
Krohne Flow Meter

Venturi flowmeter

Differential-pressure flowmeter built on a Venturi tube per EN ISO 5167 and ASME MFC-3M, made for steam, feedwater and hydrocarbon measurement and acceptance testing.

The Venturi flowmeter uses a machined, or welded and internally machined, Venturi tube as the primary element of a differential pressure (DP) measurement, with low remaining pressure loss and only short straight inlet and outlet sections. It has no wear-prone parts and needs no maintenance, so it suits live steam, wet gas, CO2 injection, hydrocarbons, LNG and refinery duties, as well as acceptance testing and billing. Tubes are manufactured and calibrated up to 48", including 20-point calibration at high Reynolds numbers, for example per ASME PTC. The assembly can include DP transmitters, valves, manifolds, a flow computer, engineering, testing and documentation, with redundancy (1oo2, 2oo3) and SIL 2/3 certified versions available.

Specifications

Design Standards
EN ISO 5167 and ASME MFC-3M
Manufacturing Capability
Up to 48"
Calibration
Special 20-point calibration at high Reynolds numbers possible (e.g. acc. to ASME PTC)
Redundancy
1oo2, 2oo3
Communication Options
HART 7, Foundation fieldbus and Profibus-PA
Safety Certification
SIL 2/3 certified versions
Hazardous Area Approvals
Ex ia, Ex d, Ex t

Enquire about this product

Pricing, availability, lead times and technical support — direct from our engineers.

Flow Measurement — talk to our engineers

Flowmeters, controllers and accessories for every process