Skip to content
Krohne Flow Meter

Flow nozzle

Differential-pressure primary element for high-velocity, non-viscous or erosive fluids, available as ISA 1932, long radius and Venturi nozzle types.

The flow nozzle generates a differential pressure for flow measurement in fluids that would wear or damage an orifice plate because of high velocity and pressure. It has no exposed sharp edges, needs shorter straight inlet and outlet runs, and causes lower permanent pressure loss than an orifice plate. It can be supplied as a pre-assembled meter run, with weld ends, with a flange connection or for mounting between two flanges, and is designed to ISO 5167, ASME MFC-3M or ASME PTC 6. A throat tap long radius nozzle to ASME PTC 6 is typically used for performance testing of steam turbines.

Specifications

Nozzle Types
ISA 1932, long radius and Venturi nozzles
Standards
ISO 5167, ASME MFC-3M or ASME PTC 6
Uncalibrated Uncertainty
Typical up to ±0.8% (ISA-1932 nozzle)
Calibrated Uncertainty
Up to ±0.2% with optional accredited wet calibration at operating Reynolds number
Pressure Loss
Typical down to 5% of the generated DP (Venturi nozzle)
Materials
Carbon steel, stainless steel and special materials
Size
2…24″ (60...630 mm) per standard, larger sizes upon request
Connections
Weld ends, flange connection or for mounting between two flanges within the bolt circle
Pressure Taps
Optional annular chamber and multiple pressure taps (redundancy)

Enquire about this product

Pricing, availability, lead times and technical support — direct from our engineers.

Pressure Measurement — talk to our engineers

Pressure and differential-pressure process instruments