Skip to content
Krohne Flow Meter

DK37 M8

All-metal variable area flowmeter for low liquid and gas flows, with mechanical indicator or 4…20 mA/HART output, up to 220 barg.

The DK37 M8 is a variable area flowmeter for liquids and gases, available with a mechanical indicator and two optional limit switches, or with an electronic indicator and 4…20 mA/HART output. Full scale is 1.6…250 l/h for liquids and 16…8,000 l/h for gases, with a 10:1 turndown ratio and a maximum error of ±2.5% (VDI/VDE 3513-2) or ±2% of full scale. A needle valve is fitted as standard for setting the flow, and the meter can measure and display without auxiliary power. It is approved for hazardous areas and suitable for SIL 2 safety instrumented systems, or SIL 3 in a redundant 1oo2 design.

Specifications

Measuring Principle
Variable area
Full Scale (Liquids)
1.6…250 l/h / 0.4…67 GPH
Full Scale (Gases)
16…8,000 l/h / 0.6…300 SCFH
Turndown Ratio
10:1
Maximum Measuring Error
±2.5% (acc. to VDI/VDE 3513-2) or ±2% of full scale
Process Temperature
-40…+150°C / +302°F
Maximum Pressure
220 barg / 3190 psig
Process Connection Thread
G¼, ¼ NPT; others
Output Signal
4…20 mA/HART
Limit Switches
2 optional
Ingress Protection
IP66/67
Housing Material
PPS as standard, stainless steel as option
Sensor Materials
Stainless steel and alloy
Functional Safety
SIL 2; SIL 3 in redundant design (1oo2), type A device

Enquire about this product

Pricing, availability, lead times and technical support — direct from our engineers.

Flow Measurement — talk to our engineers

Flowmeters, controllers and accessories for every process