Compact orifice plate flowmeter
Integral differential pressure flowmeter combining orifice plate, manifold and DP transmitter for liquids, gases and steam in DN50…600 lines.
The flowmeter builds the orifice plate, sandwich meter body, impulse lines, connection flange and OPTIBAR DP 7060 transmitter into a single unit. The orifice plate is a one-piece design per ISO 5167-2 or ASME MFC-3M, delivered pre-assembled, preconfigured and pressure tested. Because it needs no external impulse lines, valves or supports, installation effort and leakage points are reduced. It is used on applications from demineralised water to chemicals and steam, at line pressures up to 160 bar / 2320 psi and temperatures up to +400°C / +752°F.
Specifications
- Line Size
- DN50…600 / 2…24"
- Max. Process Temperature
- Up to +400°C / +752°F
- Max. Line Pressure
- 160 bar / 2320 psi
- Output / Communication
- 2-wire 4…20 mA/HART®, FF, Profibus-PA
- Flow Element Standard
- ISO 5167-2 or ASME MFC-3M
- Standard Material
- 316/316L, other materials on request
- Redundancy Options
- 1oo2, 2oo3
- Safety Integrity
- SIL 2/3 certified versions
- Hazardous Area Approvals
- Ex ia, Ex d, Ex t
- Measured Media
- Liquids, gases and steam