Skip to content
Krohne Level Transmitter

BW 25

Loop-powered displacer transmitter for continuous level, liquid-liquid interface or density measurement up to +400°C and 400 barg.

The BW 25 measures liquid level or the interface between two liquids in corrosive media at temperatures up to +400°C / +752°F and pressures up to 400 barg / 5801 psig. It is loop-powered and can work as a mechanical indicator without auxiliary power, as a level switch with a switch module, or as a transmitter with a transmitter module, and the three modes can be combined. Functions can be retrofitted without interrupting the process, and the unit can be mounted in a bypass chamber, for example for applications with agitators, turbulence or foam.

Specifications

Measuring Range
0.3…5.5 / 1…18 ft
Density
≥0.45 kg/l /≥28.1 lb/ft 3
Process Temperature
-40…+400°C / +752°F
Process Pressure
-1…400 barg / -14.5…5801 psig
Level Switch Set Points
Max. 2 set points
Bypass Chamber Materials
316L, 304L, alloy C276, alloy 625
Process Seal
Welded process seal with external mount housing

Enquire about this product

Pricing, availability, lead times and technical support — direct from our engineers.

Level Measurement — talk to our engineers

Continuous and point level measurement for liquids and solids