UC09 - Inline Infrared Carbometric Unit - Maselli Misure
Real-time inline CO2 measurement for carbonated beverages with ±0.025 v/v accuracy and automatic temperature compensation.
The UC09 inline infrared carbometric unit delivers precise CO2 quantification across the full range of 0–6 v/v (0–12 g/l) for carbonated soft drinks, beers, and mineral waters. Operating with a 3-second measurement cycle and ±0.05 g/l accuracy, the system features integrated Pt1000 temperature compensation (−5 to +35 °C) and handles process line pressures up to 10 bar at 20 °C. Scalable between v/v and g/l units, the UC09 supports standard sterilization at 100 °C or high-temperature operation at 130 °C, ensuring consistent quality control in demanding beverage production environments.
Specifications
- Application:
- Measurement of carbonated soft drinks, beer and mineral waters on process lines
- Measurement limits:
- 0…6 v/v (0…12 g/l)
- Accuracy:
- +/- 0.025 v/v (+/- 0.05 g/l)
- Measurement scales:
- “v/v (Gas/Vol)” or “g/l”
- Measurement interval:
- 3 seconds
- Product temperature during measuring:
- -5…+35 °C [23…95 °F] with automatic compensation for temperature measured by Pt1000 Temperature Probe, Class “A” according to IEC751.
- Relative line pressure
- max. 10 bar (145 psi) at 20 °C (68 °F) max. 8 bar (116 psi) at 100 °C (212 °F)
- Max. sterilization temp. (Hot water)
- 100°C (4 hours) in the Standard configuration 130°C (45 min.) in the HT configuration